APFC PANELS

APFC or Automatic Power Factor Control Panels are mainly used for the improvement of Power Factor. Power Factor can be explained as ratio of active power to apparent power and it is a key factor in measuring electrical consumption. Everyone knows that how costly electricity has become in present time. Therefore it becomes utmost important to cut down on electrical consumption for reducing expenditure.

APFC Panels come real handy in the achievement of this purpose Use of these control panels becomes indispensable in those industries where electrical installations are meant to supply to large electrical load. A dip in Power Factor can attract operational losses and a penalty from electricity board, responsible for electricity supply.We offer vide range of standard and customized APFC panels and are competitive in the industry.

APFC or Automatic Power Factor Control Panels are mainly used for the improvement of Power Factor. Power Factor can be explained as ratio of active power to apparent power and it is a key factor in measuring electrical consumption. Everyone knows that how costly electricity has become in present time. Therefore it becomes utmost important to cut down on electrical consumption for reducing expenditure.

APFC or Automatic Power Factor Control Panels are mainly used for the improvement of Power Factor. Power Factor can be explained as ratio of active power to apparent power and it is a key factor in measuring electrical consumption. Everyone knows that how costly electricity has become in present time. Therefore it becomes utmost important to cut down on electrical consumption for reducing expenditure.

Supply 3 Phase, 4 Wire
Voltage 415 V, AC
Frequency 50 Hz
Permissible voltage 1.1vn
Permissible current 1.1vn
Temperature category 50 Deg. C
Ref. Standards for i) Capacitors – IS 2834-1986 ii) Panel – IEC 439/1-2
  • 1. Payback period is 8 to 10 months
  • 2. Reduction in maximum demand
  • 3. Energy saving up to 5%
  • 4. Low power factor penalty can be avoided
  • 5. Extended life for Switch Gears, Capacitors and Cables
  • 6. Avoid manual disruptions
  • 7. Avoid high current consumption losses
  • 8. Reduction in Electricity Bill
  • 1. All major components are of standard make like Siemens, Epcos, L&T and Schneider
  • 2. Microprocessor based automatic controller with power factor display
  • 3. All components are carefully integrated for reliable performance and longer life
  • 4. Capacitor duty Contactors and MCB or MCCB, are used to switch ON capacitors to minimize switching surges
  • 5. Uses small correction steps to maintain accurate setting
  • 6. Auto / Manual Facility, Cooling Facility
  • 7. Very low watt losses
  • 8. In-built time delay for switching ON of a capacitor bank to avoid impulse signal operation. All capacitor feeders have Auto / Manual mode facility with fuse protection and isolation
  • 9. Power Factor Controllers are designed to operate, Automatically with Micro Processor Based Automatic Controller
  • 10. Use a specially designed electronic control circuit that improves power factor to meet requirements of load switching pattern
  • 11. Improvement of power factor up to optimum levels is guaranteed Product range: 20 KVAr to 1000 KVAr.
  • 12. We provide solutions for improving plant power factor by installing our APFC panel
  • 13. Heavy duty capacitors with detuned filters will be provided where high level non linear harmonies present upto 30%
Sample Description